Greenhouse CO2 Controller Plug and Play

Short Description:

Model: TKG-CO2-1010D-PP

Key words:

For greenhouses,mushrooms
CO2 and temp. Humidity control
Plug & play
Day/Light working mode
Split or extendable sensor probe

Short Description:
Specifically design to control CO2 concentration as well as temperature and humidity in greenhouses, mushrooms or other similar environment. It features a highly durable NDIR CO2 sensor with self-calibration, ensuring accuracy over its impressive 15-year lifetime.
With a plug-and-play design the CO2 controller oerates on a wide power supply range of 100VAC~240VAC, offering flexibility and comes with European or American power plug options. It includes a maximum 8A relay dry contact output for efficient control.
It incorporates a photosensitive sensor for automatic switching of day/night control mode, and its sensor probe can be used for separate sensing, with a replaceable filter and extendable lenth.


Brief Introduction

Product Tags

FEATURES

Design for control the CO2 concentration in greenhouses or mushrooms
NDIR infrared CO2 sensor inside with Self-Calibration and up to more than 10 years lifetime.
Plug & play type, very easy to connect the power and a fan or CO2 generator.
100VAC~240VAC range power supply with European or American power plug and power connector.
A max. 8A relay dry contact output
A photosensitive sensor inside for auto changeover of day/night work mode
Replaceable filter in the probe and extendable probe length.
Design the convenient and easier buttons for operation.
Optional split external sensor with 2 meter cables
CE-Approval.

TECHNICAL SPECIFICATIONS

CO2 Sensor Non-Dispersive Infrared Detector (NDIR)
 Measurement Range 0~2,000ppm (default) 0~5,000ppm (preset)
Accuracy ±60ppm + 3% of reading @22℃(72℉)
Stability <2% of full scale over the life of the sensor
Calibration Self-calibration system enable or disable
Response Time <5 minutes for 90% step change at low duct speed
Non-linearity <1% of full scale @22℃(72℉)
Duct Air Velocity 0~450m/min
Pressure Dependence 0.135% of reading per mm Hg

 

 Warm up time 2 hours (first time) / 2 minutes (operation)
Split CO2 sensor optional 2 meter cable connection between the senor and the controller
Power supply 100VAC~240VAC
Consumption 1.8 W max. ; 1.0 W avg.
LCD display Display CO2 measurement
 Dry contact output (optional) 1xdry contact output /Max. switch current: 8A (load resistance) SPDT relay
Plug& play type 100VAC~240VAC power supply with European or American power plug and power connector to the CO2 generator
Operation conditions 0℃~60℃(32~140℉); 0~99%RH, non condensing
Storage conditions 0~50℃(32~122℉)/ 0~80%RH
IP class IP30
Standard Approval CE-Approval