Designed for real time measuring ambiance carbon dioxide level, air quality (VOC’s), temperature and relative humidity.
NDIR infrared CO2 sensor inside with special Self Calibration. It makes CO2 measurement more accurate and reliable.
More than 10 years lifetime of CO2 sensor.
Mix gases sensor with high sensitivity for VOC and cigarette.
High accuracy temperature and relative humidity measurement optional
Combined both humidity and temperature sensors seamlessly with digital auto compensation
Provide up to 2 or 3 analog outputs for CO2, air quality (VOC’s) and temperature or relative humidity.
With LCD or without LCD selectable
LCD display CO2, temperature and humidity measurements as well as air quality (VOC’s) level.
Wall mounting type with easy installation.
Modbus RS485 interface with outputs for CO2, temperature, humidity and air quality (VOC’s).
24VAC/VDC power supply
EU standard
Monitoring parameters | CO2 | Air Quality (VOC’s) | Temperature | Relative humidity |
Sensing element | Non-Dispersive InfraredDetector (NDIR) | Semiconductor mixgases sensor | Digital combined temperatureand humidity sensor | |
Measuring range | 0~2000ppm(default) 0~5000ppm(selectable in the order) | 1~30ppm | 0~50℃(default)-20~60℃selectable |
0~100%RH |
Display Resolution | 1ppm | 0.1ppm | 0.1℃ |
0.1%RH |
Accuracy@25℃(77℉) | ±40ppm + 3% of reading | ±10% | ±0.5℃ |
±3%RH |
Life time | 15 years (normal) | 5~7 years | 10 years | |
Calibration cycle | ABC Logic SelfCalibration | —— | —— | —— |
Response Time | <2 minutes for 90% change | <1 minute(for 10ppm hydrogen, 30ppm ethanol)<5 minute
(for a cigarette) in 20m2 room |
<10 seconds to reach 63% | |
Warm up time | 72 hours (first time) 1 hour (operation) | |||
Electrical Characteristics | ||||
Power supply | 24VAC/VDC | |||
Consumption | 3.5 W max. ; 2.5 W avg. | |||
Outputs | Up to three analog outputs0~10VDC (default) or 4~20mA (selectable by jumpers) 0~ 5VDC (selected in placing order, cannot be changed) | |||
Modbus interface | RS-485 with Modbus protocol, 19200bps rate, 15KV antistatic protection, independent base address. |
Display and Alarm | |
LCD Display | White backlit LCD display: CO2+VOC+Temperature&Humidity measurement |
Conditions of Using and Installation | |
Operation conditions | -20~60℃(-4~140℉); 0~95%RH, non condensing |
Storage conditions | 0~50℃(32~122℉)/ 20~60%RH |
Weight | 240g |
Dimensions | 130mm(L)×85mm(W)×36.5mm(H) |
Installation | Wall mount (65mm×65mm or 85mmX85mm or 2”×4” wire box) |
Housing IP class | PC/ABS, protection class: IP30 |
Standard | CE-Approval |