Indoor Air Quality Monitor for CO2 TVOC

Short Description:

Model: G01-CO2-B5 Series
Key words:

CO2/TVOC/Temperature/Humidity detection
Wall mounting/ Desktop
On/off output optional
Indoor air quality monitor of CO2 plus TVOC(mix gases) and temperature, humidity monitoring. It has tri-color traffic display for three CO2 ranges. The buzzle alarm is available which can be turned off once the buzzer rings.
It has the optional on/off output to control a ventilator according to CO2 or TVOC measurement. It supports power supply: 24VAC/VDC or 100~240VAC, and can be easily mounted on the wall or placed on a desktop.
All parameters can be preset or adjusted if required.


Brief Introduction

Product Tags

FEATURES

Real time indoor air quality monitoring with CO2 plus TVOC and Temp.&RH
NDIR CO2 sensor with special Self-Calibration makes the CO2 measurement more accurate and more reliable.
More than 10 years lifetime of CO2 sensor
More than 5 years lifetime of Semi-conductor TVOC (mix gases) sensor
Digital temperature and humidity sensor with more than 10 years lifetime
Three-color (green/yellow/red) LCD backlight for optimal/moderate/poor ventilation levels
Buzzer alarm available
Optional 1xrelay output to control a fan
Easy operation by the touch button
Perfect performance in low cost for IAQ detection and monitoring
220VAC or 24VAC/VDC power supply selectable; power adaptor available;
Desktop and wall mounting available
Application in classrooms, offices, hotels and other public rooms

TECHNICAL SPECIFICATIONS

Monitoring parameters

CO2

TVOC

Temperature

Relative humidity

Sensor

Non-Dispersive Infrared Detector (NDIR) Semiconductor mix gases sensor Digital combined temperature and humidity sensor

Measuring range

0~5000ppm

1~30ppm

-20~60℃

0~100%RH

Display Resolution

1ppm

5ppm

0.1℃

0.1%RH

Accuracy@25(77)

±60ppm + 3% of reading

±10%

±0.5℃

±4.5%RH

Life time

15 years (normal)

5~7 years

10 years

Stability

<2%

——

<0.04℃per year <0.5%RHper year

Calibration cycle

ABC Logic Self Calibration

——

——

——

  

Response Time

  

<2 minutes for 90% change

<1 minute(for 10ppm hydrogen, 30ppm ethanol)

<5 minute

(for a cigarette) in 20m2 room

  

<10 seconds to reach 63%

Warm up time

72 hours (first time) 1 hour (operation)

Electrical Characteristics

Power supply

100~240VAC18~24VAC/VDC with the power adaptor available

Consumption

3.5 W max. ; 2.5 W avg.

Display and Alarm

  

 

 

 

LCD Display

Green CO2<1000ppm (optimal air quality) TVOC: ▬ or ▬ ▬ (low pollution) 

Yellow CO2>1000ppm (moderate air quality)

TVOC: ▬ ▬ ▬ or ▬ ▬ ▬ ▬ (medium pollution)

 

Red CO2>1400ppm (poor air quality)

TVOC: ▬ ▬ ▬ ▬ ▬ or ▬ ▬ ▬ ▬ ▬ ▬ (heavy pollution)

 

Two modes selectable: both CO2 and TVOC over the above setpoints(default)

Either CO2 or TVOC over the above setpoint

Conditions of Using and Installation

Operation conditions

-10~50℃(14~122℉); 0~95%RH, non condensing

Storage conditions

0~50℃(32~122℉)/ 5~90%RH

Weight

200g

Dimensions

130mm(L)×85mm(W)×36.5mm(H)

Installation

Desktop or wall mount (65mm×65mm or 85mmX85mm or 2”×4” wire box)

Housing IP class

PC/ABS, protection class: IP30

  • Previous:
  • Next: