CO and Ozone Monitors and Controllers

  • Ozone Gas Monitor Controller with Alarm

    Ozone Gas Monitor Controller with Alarm

    Model: G09-O3

    Ozone and Temp.& RH monitoring
    1xanalog output and 1xrelay outputs
    Optional RS485 interface
    3-color backlight display three scales of ozone gas
    Can set the control mode and method
    Zero point calibration and replaceable ozone sensor design

     

    Real-time monitoring air ozone and optional temperature and humidity. Ozone measurements have temperature and humidity compensation algorithms.
    It provides one relay output to control a ventilator or ozone generator. One 0-10V/4-20mA linear output and a RS485 to connect a PLC or other control system. Tri-color traffic LCD display for three ozone ranges. The buzzle alarm is available.

  • Carbon Monoxide Monitor

    Carbon Monoxide Monitor

    Model: TSP-CO Series

    Carbon monoxide monitor and controller with T & RH
    Sturdy shell and cost-effective
    1xanalog linear output and 2xrelay outputs
    Optional RS485 interface and availalbel buzzer alarm
    Zero point calibration and replaceable CO sensor design
    Real-time monitoring carbon monoxide concentration and temperature. OLED screen displays CO and Temperature in real time. Buzzer alarm is available. It has a stable and reliable 0-10V / 4-20mA linear output, and two relay outputs, RS485 in Modbus RTU or BACnet MS/TP. It usually be used in parking, BMS systems and other public places.

  • Carbon Monoxide Monitor and Controller

    Carbon Monoxide Monitor and Controller

    Model: GX-CO Series

    Carbon monoxide with temperature and humidity
    1×0-10V / 4-20mA linear output, 2xrelay outputs
    Optional RS485 interface
    Zero point calibration and replaceable CO sensor design
    Powerful on-site setting function to meet more applications
    Real-time monitoring air carbon monoxide concentration, displaying CO measurements and 1-hour average. Temperature and relative humidity is optional. High quality Japanese sensor has five years liftime and is replaceable conveniently. Zero calibration and CO sensor replacement can be handled by end users. It provides one 0-10V / 4-20mA linear output, and two relay outputs, and optional RS485 with Modbus RTU. Buzzer alarm is available or disable, it’s widely used in BMS systems and ventilation control systems.

  • Ozone Split Type Controller

    Ozone Split Type Controller

    Model: TKG-O3S Series
    Key words:
    1xON/OFF relay output
    Modbus RS485
    External sensor probe
    Buzzle alarm

     

    Short Description:
    This device is designed for real-time monitoring of air ozone concentration. It features an electrochemical ozone sensor with temperature detection and compensation, with optional humidity detection. The installation is split, with a display controller separate from the external sensor probe, which can be extended into ducts or cabins or placed elsewhere. The probe includes a built-in fan for smooth airflow and is replaceable.

     

    It has outputs for controlling an ozone generator and ventilator, with both ON/OFF relay and analog linear output options. Communication is via Modbus RS485 protocol. An optional buzzer alarm can be enabled or disabled, and there’s a sensor failure indicator light. Power supply options include 24VDC or 100-240VAC.

     

  • Basic Carbon Monoxide Sensor

    Basic Carbon Monoxide Sensor

    Model: F2000TSM-CO-C101
    Key words:
    Carbon dioxide sensor
    Analog linear outputs
    RS485 interface
    Low-cost carbon monoxide transmitter for ventilation systems. Within a high quality Japanese sensor and its long lifetime support, the linear output of 0~10VDC/4~20mA is stable and reliable. Modbus RS485 communication interface has 15KV anti-static protection which can connect to a PLC to control ventilation system.

  • CO controller with BACnet RS485

    CO controller with BACnet RS485

    Model: TKG-CO Series

    Key words:
    CO/Temperature/Humidity detection
    Analog linear output and optional PID output
    On/off relay outputs
    Buzzer alarm
    Underground parking lots
    RS485 with Modbus or BACnet

     

    Design for control carbon monoxide concentration in undergroung parking lots or semi underground tunnels. With a high quality Japanese sensor it provides one 0-10V / 4-20mA signal output to integrate into PLC controller, and two relay outputs to control ventilators for CO and Temperature. RS485 in Modbus RTU or BACnet MS/TP communication is optional. It displays carbon monoxide in real time on the LCD screen, also optional temperature and relative humidity. The design of external sensor probe can avoid internal heating of the controller from affecting measurements.

  • Ozone O3 Gas Meter

    Ozone O3 Gas Meter

    Model: TSP-O3 Series
    Key words:
    OLED display optional
    Analog outputs
    Relay dry contact outputs
    RS485 with BACnet MS/TP
    Buzzle alarm
    Real-time monitoring air ozone concentration . Alarm buzzle is available with setpoint preset. Optional OLED display with operation buttons. It provides one relay output to control an ozone generator or ventilator with two control way and setpoints selection, one analog 0-10V/4-20mA output for ozone measurement.