CO and Ozone Monitors and Controllers
-
Ozone Gas Monitor Controller with Alarm
Model: G09-O3
Ozone and Temp.& RH monitoring
1xanalog output and 1xrelay outputs
Optional RS485 interface
3-color backlight display three scales of ozone gas
Can set the control mode and method
Zero point calibration and replaceable ozone sensor designReal-time monitoring air ozone and optional temperature and humidity. Ozone measurements have temperature and humidity compensation algorithms.
It provides one relay output to control a ventilator or ozone generator. One 0-10V/4-20mA linear output and a RS485 to connect a PLC or other control system. Tri-color traffic LCD display for three ozone ranges. The buzzle alarm is available. -
Carbon Monoxide Monitor
Model: TSP-CO Series
Carbon monoxide monitor and controller with T & RH
Sturdy shell and cost-effective
1xanalog linear output and 2xrelay outputs
Optional RS485 interface and availalbel buzzer alarm
Zero point calibration and replaceable CO sensor design
Real-time monitoring carbon monoxide concentration and temperature. OLED screen displays CO and Temperature in real time. Buzzer alarm is available. It has a stable and reliable 0-10V / 4-20mA linear output, and two relay outputs, RS485 in Modbus RTU or BACnet MS/TP. It usually be used in parking, BMS systems and other public places. -
Carbon Monoxide Monitor and Controller
Model: GX-CO Series
Carbon monoxide with temperature and humidity
1×0-10V / 4-20mA linear output, 2xrelay outputs
Optional RS485 interface
Zero point calibration and replaceable CO sensor design
Powerful on-site setting function to meet more applications
Real-time monitoring air carbon monoxide concentration, displaying CO measurements and 1-hour average. Temperature and relative humidity is optional. High quality Japanese sensor has five years liftime and is replaceable conveniently. Zero calibration and CO sensor replacement can be handled by end users. It provides one 0-10V / 4-20mA linear output, and two relay outputs, and optional RS485 with Modbus RTU. Buzzer alarm is available or disable, it’s widely used in BMS systems and ventilation control systems. -
Ozone Split Type Controller
Model: TKG-O3S Series
Key words:
1xON/OFF relay output
Modbus RS485
External sensor probe
Buzzle alarmShort Description:
This device is designed for real-time monitoring of air ozone concentration. It features an electrochemical ozone sensor with temperature detection and compensation, with optional humidity detection. The installation is split, with a display controller separate from the external sensor probe, which can be extended into ducts or cabins or placed elsewhere. The probe includes a built-in fan for smooth airflow and is replaceable.It has outputs for controlling an ozone generator and ventilator, with both ON/OFF relay and analog linear output options. Communication is via Modbus RS485 protocol. An optional buzzer alarm can be enabled or disabled, and there’s a sensor failure indicator light. Power supply options include 24VDC or 100-240VAC.
-
Basic Carbon Monoxide Sensor
Model: F2000TSM-CO-C101
Key words:
Carbon dioxide sensor
Analog linear outputs
RS485 interface
Low-cost carbon monoxide transmitter for ventilation systems. Within a high quality Japanese sensor and its long lifetime support, the linear output of 0~10VDC/4~20mA is stable and reliable. Modbus RS485 communication interface has 15KV anti-static protection which can connect to a PLC to control ventilation system. -
CO controller with BACnet RS485
Model: TKG-CO Series
Key words:
CO/Temperature/Humidity detection
Analog linear output and optional PID output
On/off relay outputs
Buzzer alarm
Underground parking lots
RS485 with Modbus or BACnetDesign for control carbon monoxide concentration in undergroung parking lots or semi underground tunnels. With a high quality Japanese sensor it provides one 0-10V / 4-20mA signal output to integrate into PLC controller, and two relay outputs to control ventilators for CO and Temperature. RS485 in Modbus RTU or BACnet MS/TP communication is optional. It displays carbon monoxide in real time on the LCD screen, also optional temperature and relative humidity. The design of external sensor probe can avoid internal heating of the controller from affecting measurements.
-
Ozone O3 Gas Meter
Model: TSP-O3 Series
Key words:
OLED display optional
Analog outputs
Relay dry contact outputs
RS485 with BACnet MS/TP
Buzzle alarm
Real-time monitoring air ozone concentration . Alarm buzzle is available with setpoint preset. Optional OLED display with operation buttons. It provides one relay output to control an ozone generator or ventilator with two control way and setpoints selection, one analog 0-10V/4-20mA output for ozone measurement.